Rocksolid Light

Welcome to RetroBBS

mail  files  register  newsreader  groups  login

Message-ID:  

Beam me up, Scotty!


devel / comp.protocols.dicom / Re: Dicom tag 0018,115e measured in dGy*cm*cm?

SubjectAuthor
o Re: Dicom tag 0018,115e measured in dGy*cm*cm?mamat...@gmail.com

1
Re: Dicom tag 0018,115e measured in dGy*cm*cm?

<19308a79-28d3-48cf-8ebc-47d99d725cffn@googlegroups.com>

  copy mid

https://www.rocksolidbbs.com/devel/article-flat.php?id=385&group=comp.protocols.dicom#385

  copy link   Newsgroups: comp.protocols.dicom
X-Received: by 2002:a05:6214:2608:b0:440:f018:5e1e with SMTP id gu8-20020a056214260800b00440f0185e1emr3314867qvb.40.1648107514602;
Thu, 24 Mar 2022 00:38:34 -0700 (PDT)
X-Received: by 2002:ac8:7fc1:0:b0:2e1:e519:93d5 with SMTP id
b1-20020ac87fc1000000b002e1e51993d5mr3337405qtk.508.1648107514251; Thu, 24
Mar 2022 00:38:34 -0700 (PDT)
Path: i2pn2.org!i2pn.org!weretis.net!feeder6.news.weretis.net!news.misty.com!border2.nntp.dca1.giganews.com!nntp.giganews.com!news-out.google.com!nntp.google.com!postnews.google.com!google-groups.googlegroups.com!not-for-mail
Newsgroups: comp.protocols.dicom
Date: Thu, 24 Mar 2022 00:38:34 -0700 (PDT)
In-Reply-To: <02f1f8db-7b41-42d2-bf9c-e3d884ce3ccd@googlegroups.com>
Injection-Info: google-groups.googlegroups.com; posting-host=165.225.123.194; posting-account=XaP8zAoAAACdb7KqlDoWW2aBe_oOjKXr
NNTP-Posting-Host: 165.225.123.194
References: <02f1f8db-7b41-42d2-bf9c-e3d884ce3ccd@googlegroups.com>
User-Agent: G2/1.0
MIME-Version: 1.0
Message-ID: <19308a79-28d3-48cf-8ebc-47d99d725cffn@googlegroups.com>
Subject: Re: Dicom tag 0018,115e measured in dGy*cm*cm?
From: mamatha.gn@gmail.com (mamat...@gmail.com)
Injection-Date: Thu, 24 Mar 2022 07:38:34 +0000
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable
Lines: 18
 by: mamat...@gmail.com - Thu, 24 Mar 2022 07:38 UTC

On Tuesday, March 29, 2016 at 5:16:55 PM UTC+5:30, jaapgu...@gmail.com wrote:
> Hi All,
>
> For a study I am calculating the radiotion dose of several x-rays (in mSv) using a montecarlo programme. This calculation makes use of the Area Dose Product (ADP) (dicom tag 0018,115e). Dicom lookup says that this is measured in dGy*cm*cm. But the dicom information differs a lot: some x-rays have a Area Dose Product of almost 2000 times the other, for the same kind of x-ray (same bodypart scanned, same KVP). This results in a very big variation in radiation dosis. Is it possible that some of these ADP are measured in a different order of magnitude? For example mGy*cm*cm or Gy*cm*cm of Gy*m*m?
>
> Many thanks!
Hi all,

i also have the same questions, can some experts please let us know what unit is followed while encoding the value in 0018,115e